Attached are the requirements for integration between WiNG 5.2 and ADSP system.  Following these guidelines you should be able to minimize challenges with SNMP integration between WiNG 5.2 and ADSP.

WiNG v5.2.x with Air Defense Services Platform 8.1.3b2 & 9.0 Integration Configuration Best Practices

 

Required Firmware Versions:

WiNG v5

5.2.11 or newer
5.3.1 or newer

ADSP

ADSP 8.1.3 -11b2 or ADSP 8.1.3-11e1

ADSP 9.0 or newer

Recommended Configurations:

Following are the required configurations for WING and ADSP integration

ADSP Communication Profile Settings

1)      SNMP timeout – Increase the timeout value 10 seconds (9999ms). The larger the timeout, the more reliable the system operation will be.

 

ADSP Polling Profile Settings

2)      Data Poll Interval – 

a)       Status poll interval -- 30 minutes or more.

b)      Data Collection interval -- 60 minutes or more. .

ADSP Polling

3)      In a network topology where there are controllers in the network, the polling should be set up only on the RFS Controllers, and not directly to the Access Points . It is only necessary to poll the controller as it  has all required information for the network.  Configure ADSP  to poll only the controllers, and not the APs.

 

AP and Controller Firmware Versions

4)      Only identical versions of firmware are supported for AP adoption.  Deployed systems where the controller is running a different firmware version from the AP is not a supported configuration.    Integration between WiNG and ADSP would also not be supported in this type of deployment.  Ensure deployments have identical versions of Controller and AP firmware.