CoreScanner RFID Command Status error

// Expert user has replied.
J Jason Frost 5 months 1 week ago
63 1 0

I'm using CoreScanner API in C# to read and write RFID data with DS99008R.  Scanner is set to SNAPI mode and it reads RFID tag on the trigger, but whenever I use CoreScanner to read or write to the tag it returns RFID_COMMAND_STATUS of 5.  Problem is "5" isn't listed as a status code.  Below is an example of what I'm sending (this is just a Read).  I know that it is finding the tag because if I give it a different EPC I get return code "2" which is "Tag not found".  Anyone got any ideas what I'm doing wrong? 

<inArgs>
	<scannerID>1</scannerID>
	<cmdArgs>
		<arg-xml>
			<attrib_list>

				<attribute>
					<id>35002</id>
					<datatype>A</datatype>
					<value>0x00 0x0C 0xE2 0x80 0x69 0x95 0x00 0x00 0x50 0x16 0x3F 0x14 0x4A 0xC5</value>
				</attribute>
				<attribute>
					<id>35003</id>
					<datatype>B</datatype>
					<value>1</value>
				</attribute>
				<attribute>
					<id>35005</id>
					<datatype>W</datatype>
					<value>2</value>
				</attribute>
				<attribute>
					<id>35006</id>
					<datatype>W</datatype>
					<value>0</value>
				</attribute>
				<attribute>
					<id>35008</id>
					<datatype>B</datatype>
					<value>1</value>
				</attribute>
			</attrib_list>
		</arg-xml>
	</cmdArgs>
</inArgs>
Please register or login to post a reply

1 Replies

R Robert Arneson

Hi Jason,

There was a similar discussion with same type question. I recommend to downloading the Scanner WMI test tool in helping you with your problem. There also is a support community article on this topic that can be found at the following link.

 https://supportcommunity.zebra.com/s/article/Write-a-tag-data-with-DS9908R?language=en_US

Best regards,

CONTACT
Can’t find what you’re looking for?